HPLC and spectroscopy grades are defined by what the detector sees. For UV work the critical parameter is transmittance at low wavelengths, so solvents are specified by their UV cut-off and absorbance at stated wavelengths rather than assay alone. Molychem manufactures HPLC-grade acetonitrile, methanol gradient grade, water, THF, TFA, triethylamine, MTBE, hexane and MOLYSOL 'E'.
1 to 29 of 29 item(s) displayed
| Code | Product Name | CAS | HSN Code | Packing | MSDS | Specs | COAs |
|---|---|---|---|---|---|---|---|
| 42100 | 1,4-DIOXAN FOR HPLC & UV SPECTROSCOPY | 123-91-1 | 29329900 |
1LTR |
|
|
|
| 42600 | 2,2,2-TRICHLOROETHANOL 98% For HPLC | 115-20-8 | 29055998 |
100GM |
- | - | - |
| 42900 | 2,2,4-TRIMETHYLPENTANE (iso-Octane) FOR HPLC | 540-84-1 | 29011000 |
1LTR 2.5LTR |
|
|
|
| 40980 | ACETONE FOR HPLC | 67-64-1 | 29141100 |
1LTR 2.5LTR |
|
|
|
| 41000 | ACETONITRILE FOR HPLC | 75-05-8 | 29269000 |
1LTR 2.5LTR |
|
|
|
| 41090 | ACETONITRILE HPLC GRADIENT GRADE | 75-05-8 | 29269000 |
1LTR 2.5LTR |
|
|
|
| 41038 | CARBON TETRACHLORIDE HPLC | 56-23-5 | 29031400 |
1LTR |
|
|
|
| 41050 | CHLOROFORM FOR HPLC | 67-66-3 | 29031300 |
1LTR 2.5LTR |
|
|
|
| 41039 | CYCLOHEXANE HPLC | 110-82-7 | 29021100 |
1LTR |
|
|
|
| 41092 | DICHLOROMETHANE 99.8% FOR HPLC | 75-09-2 | 29031200 |
1LTR 2.5LTR |
|
|
|
| 42060 | DIMETHYL SULPHOXIDE HPLC | 67-68-5 | 29309099 |
1LTR |
|
|
|
| 42000 | DIMETHYLFORMAMIDE FOR HPLC | 68-12-2 | 29211110 |
1LTR |
|
|
|
| 42300 | ETHYL ACETATE HPLC/UV SPECTROSCOPY | 141-78-6 | 29153100 |
1LTR 2.5LTR |
|
|
|
| 41100 | iso-PROPYL ALCOHOL HPLC SPECTROSCOPY | 67-63-0 | 29051220 |
1LTR 2.5LTR |
|
|
|
| 41060 | METHANOL “GRADIENT GRADE” FOR HPLC | 67-56-1 | 29051100 |
1LTR 2.5LTR |
|
|
|
| 41040 | METHANOL FOR HPLC | 67-56-1 | 29051100 |
1LTR 2.5LTR |
|
|
|
| 41080 | MOLYSOL ‘E’ FOR HPLC | 64-17-5 | 98020000 |
500ML |
|
- |
|
| 41081 | MOLYSOL ‘E’ FOR UV SPECTROSCOPY | 64-17-5 | 98020000 |
500ML |
- | - | - |
| 41030 | n-BUTANOL FOR HPLC & SPECTOSCOPY | 71-36-3 | 29051300 |
1LTR 2.5LTR |
|
|
|
| 41071 | n-HEPTANE 99% FOR HPLC | 142-82-5 | 29012990 |
1LTR |
|
|
|
| 41070 | n-HEXANE FOR HPLC 95% | 110-54-3 | 29011000 |
1LTR 2.5LTR |
|
|
|
| 41072 | n-HEXANE FOR HPLC 99% | 110-54-3 | 29011000 |
1LTR 2.5LTR |
|
|
|
| 41085 | N-PENTANE FOR HPLC/SPECTROSCOPY | 109-66-0 | 29012990 |
1LTR |
|
|
|
| 41035 | tert-BUTYL METHYL ETHER FOR HPLC 99.7% | 1634-04-4 | 29091900 |
1LTR 2.5LTR |
|
|
|
| 19345 | TETRAHYDROFURAN FOR HPLC | 109-99-9 | 29321100 |
1LTR 2.5LTR |
|
|
|
| 42400 | TOLUENE FOR HPLC / UV SPECTOSCOPY | 108-88-3 | 29023000 |
1LTR 2.5LTR |
|
|
|
| 42800 | TRIETHYLAMINE HPLC | 121-44-8 | 29211990 |
500ML 1LTR |
|
|
|
| 54150 | TRIFLUOROACETIC ACID HPLC | 76-05-1 | 29159090 |
100ML 500ML |
|
|
|
| 32230 | WATER FOR HPLC &SPECTROSCOPY | 7732-18-5 | 28539010 |
1LTR 5LTR |
|
|
|
Note:
HPLC grade solvents are purified and filtered to minimise UV absorbance, particulates and non-volatile residue, so they do not produce baseline noise or ghost peaks. Molychem supplies 29 HPLC and spectroscopy grade solvents including Acetonitrile, Methanol and Acetone.
HPLC grade solvents are purified and filtered to minimise UV absorbance, particulates and non-volatile residue, so they do not produce baseline noise or ghost peaks. Molychem supplies 29 HPLC and spectroscopy grade solvents including Acetonitrile, Methanol and Acetone.
Acetonitrile and methanol are the standard organic modifiers, paired with HPLC grade water. Water for HPLC & Spectroscopy matters as much as the organic solvent — ordinary distilled water introduces the same baseline problems the purified solvents are meant to avoid.
The additional cost covers UV transparency testing, sub-micron filtration and low residue-on-evaporation limits that AR specification does not require. For work that is not chromatographic, high purity AR and LR solvents are the appropriate and more economical choice.
Trifluoroacetic Acid HPLC is the common mobile-phase additive for peptide and protein separations, improving peak shape. Triethylamine HPLC is used as a basic modifier to suppress tailing on silica-based columns.
Tetrahydrofuran for HPLC forms explosive peroxides on exposure to air and light, so it is supplied stabilised, should be stored sealed away from light, and must be peroxide-tested before use if stored long. It also swells PEEK tubing and some column frits, so system compatibility should be checked first.
Normal-phase separations use non-polar hydrocarbons as the base solvent, modified with a small percentage of a polar solvent. Molychem supplies n-Hexane for HPLC 99%, n-Heptane 99% for HPLC and iso-Octane for HPLC for this purpose.
Every batch ships with a Certificate of Analysis stating actual tested values for UV absorbance, water content and residue, plus MSDS and specification sheet. The same standard applies across inorganic acids and the wider laboratory chemicals range.